The Camera and Readout for the Trinity Demonstrator and the EUSO-SPB2 Cherenkov Telescope
classification
🌌 astro-ph.IM
astro-ph.HEhep-exphysics.ins-det
keywords
cameracamerascherenkovsipmsdemonstratoreuso-spb2pixeltelescope
read the original abstract
We developed a modular silicon photomultiplier camera to detect Earth-skimming PeV to EeV tau neutrinos with the imaging atmospheric Cherenkov technique. We built two cameras, a 256-pixel camera with S14161-6050HS SiPMs for the Trinity Demonstrator located on Frisco Peak, Utah, and a 512-pixel camera with S14521-6050AN SiPMs for the EUSO-SPB2 Cherenkov Telescope. The front-end electronics are based on the eMUSIC ASIC, and the camera signals are sampled and digitized with the 100MS/s and 12-bit AGET system. Both cameras are liquid-cooled. We detail the camera concept and the results from characterizing the SiPMs, bench testing, and calibrating the two cameras.
This paper has not been read by Pith yet.