REVIEW 4 cited by
SPARCL: SPectra Analysis and Retrievable Catalog Lab
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
SPectra Analysis and Retrievable Catalog Lab (SPARCL) at NOIRLab's Astro Data Lab was created to efficiently serve large optical and infrared spectroscopic datasets. It consists of services, tools, example workflows and currently contains spectra for over 7.5 million stars, galaxies and quasars from the Sloan Digital Sky Survey (SDSS) and the Dark Energy Spectroscopic Instrument (DESI) survey. We aim to eventually support the broad range of spectroscopic datasets that will be hosted at NOIRLab and beyond. Major elements of SPARCL include capabilities to discover and query for spectra based on parameters of interest, a fast web service that delivers desired spectra either individually or in bulk as well as documentation and example Jupyter Notebooks to empower users in their research. More information is available on the SPARCL website (https://astrosparcl.datalab.noirlab.edu).
Forward citations
Cited by 4 Pith papers
-
AT 2022csn: A Photometrically Peculiar Optical/UV Tidal Disruption Event in a Type II AGN
AT 2022csn is a luminous optical/UV tidal disruption event with an 18-day double-peaked light curve, low blackbody temperature, and large radius, hosted by a likely Type II AGN.
-
Generalization from Low- to Moderate-Resolution Spectra with Neural Networks for Stellar Parameter Estimation: A Case Study with DESI
Pre-trained MLPs on LAMOST low-resolution spectra generalize to DESI medium-resolution spectra for [Fe/H] and [α/Fe], outperforming the DESI SP pipeline in zero-shot and improving with modest fine-tuning.
-
The Backup Program of the Dark Energy Spectroscopic Instrument's Milky Way Survey
The Milky Way Backup Program will deliver about 10 million stellar spectra over 21,000 square degrees using less than 9 percent of DESI observing time, roughly doubling the DESI Milky Way Survey sample.
-
Finetuning Stellar Spectra Foundation Models with LoRA
With LoRA fine-tuning on 89 labeled DESI stars, SpecCLIP's [Fe/H] scatter on a 396-star test set drops from 0.256 to 0.202 dex for the best configuration.
Discussion (0). Continue with ORCID to comment.