Recognition: unknown
MWPC prototyping and performance test for the STAR inner TPC upgrade
read the original abstract
A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6$\%$ and wire pitch precision better than 10 $\mu$m. The gas gain uniformity and energy resolution are measured to be better than 1$\%$ (RMS) and 20$\%$ (FWHM), respectively, using an $^{55}$Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. The test results show that the constructed iTPC prototype meets all project requirements.
This paper has not been read by Pith yet.
Forward citations
Cited by 1 Pith paper
-
Non-Monotonicity of Transverse Momentum Correlations in Au + Au Collisions at RHIC
First measurements of pT correlations in Au+Au collisions at 3-7.7 GeV reveal non-monotonic energy dependence in central events with 5 sigma significance, breaking 1/sqrt(N_part) scaling.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.