Pith. sign in

REVIEW 2 cited by

FluoroSAM: A Language-promptable Foundation Model for Flexible X-ray Image Segmentation

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2403.08059 v3 pith:I2TBTHRN submitted 2024-03-12 cs.CV cs.AIcs.CLcs.LG

classification cs.CVcs.AIcs.CLcs.LG
keywords imagex-rayfluorosamanalysismodelsdatafoundationimages
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Language promptable X-ray image segmentation would enable greater flexibility for human-in-the-loop workflows in diagnostic and interventional precision medicine. Prior efforts have contributed task-specific models capable of solving problems within a narrow scope, but expanding to broader use requires additional data, annotations, and training time. Recently, language-aligned foundation models (LFMs) -- machine learning models trained on large amounts of highly variable image and text data thus enabling broad applicability -- have emerged as promising tools for automated image analysis. Existing foundation models for medical image analysis focus on scenarios and modalities where large, richly annotated datasets are available. However, the X-ray imaging modality features highly variable image appearance and applications, from diagnostic chest X-rays to interventional fluoroscopy, with varying availability of data. To pave the way toward an LFM for comprehensive and language-aligned analysis of arbitrary medical X-ray images, we introduce FluoroSAM, a language-promptable variant of the Segment Anything Model, trained from scratch on 3M synthetic X-ray images from a wide variety of human anatomies, imaging geometries, and viewing angles. These include pseudo-ground truth masks for 128 organ types and 464 tools with associated text descriptions. FluoroSAM is capable of segmenting myriad anatomical structures and tools based on natural language prompts, thanks to the novel incorporation of vector quantization (VQ) of text embeddings in the training process. We demonstrate FluoroSAM's performance quantitatively on real X-ray images and showcase on several applications how FluoroSAM is a key enabler for rich human-machine interaction in the X-ray image acquisition and analysis context. Code is available at https://github.com/arcadelab/fluorosam.

Discussion (0). Continue with ORCID to comment.

Forward citations

Cited by 2 Pith papers

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score. Full citation record

  1. Self-Supervised Multiview Xray Matching

    cs.CV 2025-06 conditional novelty 6.0 of 10

    Synthetic CT-derived X-ray pairs teach a transformer to match points across views, and this pretraining improves multi-view fracture classification on real X-rays.

  2. Intelligent Control of Robotic X-ray Devices using a Language-promptable Digital Twin

    cs.RO 2024-12 conditional novelty 6.0 of 10

    A language-promptable digital twin, built from text-driven X-ray segmentation, lets surgeons control a robotic C-arm by voice to visualize, collimate, and find views of requested anatomy.

Pith tools