REVIEW 2 cited by
High Precision Differential Abundance Measurements in Globular Clusters: Chemical Inhomogeneities in NGC 6752
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
High Precision Differential Abundance Measurements in Globular Clusters: Chemical Inhomogeneities in NGC 6752
read the original abstract
We report on a strictly differential line-by-line analysis of high quality UVES spectra of bright giants in the metal-poor globular cluster NGC 6752. We achieved high precision differential chemical abundance measurements for Fe, Na, Si, Ca, Ti, Cr, Ni, Zn, Y, Zr, Ba, La, Ce, Pr, Nd, Sm, Eu and Dy with uncertainties as low as ~0.01 dex (~2%). We obtained the following main results. (1) The observed abundance dispersions are a factor of ~2 larger than the average measurement uncertainty. (2) There are positive correlations, of high statistical significance, between all elements and Na. (3) For any pair of elements, there are positive correlations of high statistical significance, although the amplitudes of the abundance variations are small. Removing abundance trends with effective temperature and/or using a different pair of reference stars does not alter these results. These abundance variations and correlations may reflect a combination of (a) He abundance variations and (b) inhomogeneous chemical evolution in the pre- or proto-cluster environment. Regarding the former, the current constraints on Delta Y from photometry likely preclude He as being the sole explanation. Regarding the latter, the nucleosynthetic source(s) must have synthesised Na, alpha, Fe-peak and neutron-capture elements and in constant amounts for species heavier than Si; no individual object can achieve such nucleosynthesis. We speculate that other, if not all, globular clusters may exhibit comparable abundance variations and correlations to NGC 6752 if subjected to a similarly precise analysis.
Forward citations
Cited by 2 Pith papers
-
The complex stellar system M 22: constraining the chemical enrichment from AGB stars using magnesium isotope ratios
First Mg isotope measurements at [Fe/H]≈-2 in a globular cluster show no difference tied to s-process enrichment, favoring ~2.75 M_sun AGB polluters and a 280–480 Myr age gap.
-
The complex stellar system M 22: confirming abundance variations with high precision differential measurements
High-precision differential abundances confirm M 22 hosts a >0.24 dex iron spread and ~0.65 dex s-process spread, and reveal new internal abundance variations within each population.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.